Tuesday, 2 June 2009

Legacy Habitat Times - Latest Newsletter

Our latest Legacy Habitat Times newsletter is now available for download from our news page, along with previous issues:
Click image below:



Providing recent news of our newt fencing, water vole fencing and other wildlife fencing activities.

Unimog Maintenance

Its maintenance time again...
"Unimogs are great bits of kit,... if you look after them."
A phrase we have heard many times since taking delivery of our U1600 Mercedes Unimog from Atkinson VOS Ltd.
As with any vehicle of 25 years there is always going to be some issues to address.
Ours had started producing some smoke from the exhaust after working particularly hard on a water vole fencing job in Essex. There was also a fairly strong smell of partially burnt diesel. This called for some examination of the big block of iron at the heart of the beast... the 6 litre, 6 cylinder engine.

First of all, we had to raise the cab to give all-round access to the power unit. Unimogs do have a removeable bonnet and front grill but this only gives partial access to the engine.
On examination we discovered that our Unimog didn't have the necessary hydraulic, hand-pumped ram fitted to raise the cab so we had to use an arrangement of lifting gear and lifting straps to do this job. Suprisingly few pipes, cables and other services required disconnecting before raising the cab. Only the air intake pipe from the air filter, and a couple of heater hoses.

With the cab raised it was possible to get clear access to the top of the engine. We employed our local mechanic, Ryan from 'The Garage' to do the engine work for us. Rocker cover was removed and diesel injectors prised out of the block. These were sent away for testing. Diesel injectors should produce a nice uniform spray pattern, testing showed ours to produce more of a dribble. This clearly explains the smell of partialy burnt diesel and reduced engine performance. New diesel injectors were fitted and diesel filters replaced to help protect these new injectors.

Lowering the cab was more tricky than lifting. First of all we had to ensure that the splined steering column shaft lined up with its other half (The steering column separates when lifting the cab). It was then a case of very gently lowering the cab to its mountings whilst a collegue checked that no wires, pipes, fingers or other bits n bobs were going to be trapped when the cab came to rest.

Once the cab was back sitting on its mountings, the 4 securing bolts on the floor pan, inside the cab, could be put back in place. 3 of the bolts went in ok but one could not be located due to a very slight misalignment of the cab. The cab must have twisted very slightly on its pivot points when lifting. With 3 of the bolts in place, we started the engine and drove a short distance to allow the vibration to seat that cab correctly, enabling the 4th bolt to be fixed.

Thursday, 14 May 2009

Rhododendron Control


Year 4 at Shorne Wood Country Park (Kent County Council) rhododendron control. With one more winter period of removal to complete, things are looking good. Brewers Wood was year one clearance and I was starting to wonder whether we'd ever get on top of regrowth, but this weeks' follow up has been a revelation. There is now very little regrowth from remnant stumps and no signs of seedling regen. Birch, sweet chestnut, ash and oak seedlings abound as well as vigourous ground cover like bramble and bracken.

The woodland rides have been opened up and the entire woodland floor is much lighter with large flushes of bluebell. By year seven all five clerance areas should be rhodi free!
The organic grazing compartment cannot be sprayed and so a five tonne 360 is being used to grub out remnant stumps around the stands of birch and wind blown chestnuts; victims of the 1987 storm.

Wednesday, 22 April 2009

Caterpillar Skidsteer Track Replacement & Maintenance

Legacy Habitat Management recently undertook some major overhauling of the running gear on their workhorse Caterpillar Skidsteer 277B. Since owning this machine it has put in many hours hard labour resulting the need to replace the much worn rubber tracks. We decided to undertake this work ourselves and ordered the necessary tracks from Finning (UK) Ltd.

We also had to purchase the appropriate track tensioning tool from Finning as this was missing from our machine.

First process was to jack up the Cat 277B Skidsteer so that each track was clear of the ground by at least 3 inches. The lifting was done with 2 trolley jacks allowing the machine to come to rest on 4 x 2 tonne axle stands, one at each corner of the floor pan.

Tension was released from the track by undoing the bolts on the tensioning wheel. The track tensioning tool was then used to crank the drive sprocket unit forward to give more slack to the rubber track. All bolts holding these units in place had to be soaked in penetrating oil prior before they could be shifted and some had to be grinded off, to be replaced later.

The drive sprocket was then removed to allow for complete removal of the track. Some careful, but forceful ‘crowbaring ‘ was still required to remove the track fully, pulling the track over the front idler set first.

If undertaking these works yourself, be prepared to have a can of worms opened for you at this point. We discovered worn bogie/idler wheel bearings, bogie hubs, which were supposed to be full of hub oil, completely dry and empty, and perished wheel rubber. All of these issues needed addressing before replacing the tracks, we’re hoping not to have these tracks off again for some time, if ever. Make sure you have the means to remove a 5/16” grub screw from the hubs for oiling, a normal allen key may not be suitable, we snapped a few in the process, they are very tight.

After completion of oiling all the hubs and replacing necessary parts it was time to wrestle with the new tracks. Lifting gear is required to move them in to place. Bogie wheel rubbers and the insides of the tracks were coated in washing up liquid to ease the installation of the new tracks. Tracks where lined up alongside running gear and levered into place using crowbars as ‘tyre levers’, locating the track over the front idler wheels first.

After levering the rest of the track in to place, no mean feat, the drive sprocket was reassembled and unit cranked back in to place using the tensioning tool. A number of bolts that had to be ground off for removal were replaced, tracks could then be re-tensioned, we were then good to go............ not quite, next on the list, a leaky water-pump, but that’s another story......

Wednesday, 8 April 2009

We're "Tweeting"


Follow wildlifefencing.co.uk on Twitter for news of product updates and activities.
Click the above link and follow username: wildlifefencing.

Monday, 30 March 2009

Low Impact Newt Fencing

Legacy Habitat Management has recently carried out newt fencing works on part of the gas pipeline project for West Burton Power Station. Due to the sensitive nature of ground conditions and top- soil structure in some places, newt fencing had to be installed with as little ground disturbance as possible.

Newt fencing installation methods usually require cutting a trench much wider than the fencing material itself, inserting the fencing and then backfilling the remainder of the trench. This creates unnecessary soil disturbance due to the extra width of the excavated trench.

Legacy Habitat Management has developed an installation system that only requires making a very narrow slot through the top soil in which the newt fence is tightly fitted. This reduces ground disturbance and produces very little spoil, also reducing the need for time consuming back filling. Back filling, can often be the cause of weak points in a newt fence.

Minimal ground disturbance along the fence line can been seen in the above photo of a freshly installed newt fence.


Tuesday, 24 March 2009

Water Vole Fencing

Legacy Habitat Management recently installed 800m of it's water vole fencing system around two ditches for EDF at West Burton Power Station.
The first ditch had to be cleared of its water vole population to allow extension of the ash tip and a newly profiled receptor ditch was fenced and protected with rabbit fencing.
Rigorous standards were required by the client both for the water vole fencing and the H&S systems and proceedures.